* True On-Line UPS Systems
(1.0 KVA to 200.0 KVA)
Isolation Technology, ETDC Tested |
|
* True On-Line UPS Systems
(1.0 KVA to 3.0 KVA) - High Frequency Technology |
 |
|
 |
True On-Line Double Conversion Technology with Galvanic Isolation
When main power is present, the UPS converts the input AC voltage to DC to charge the battery and to supply the inverter with energy. The inverter generates a sinewave AC voltage which is permanently available at the output of the UPS through an isolating transformer. If a problem occurs with the main power supply, the battery delivers the necessary power to the inverter, additional bypass system which is integrated into the UPS guarantees the highest possible level or reliability. In cases of overload or short circuit, the bypass system automatically connects the main power input directly through to the electrical load.
True On-Line UPS Systems - Standard Specification
Parameters |
ISOLATION TECHNOLOGY |
HIGH FREQUENCY
(W/O ISOLATION) |
Single Phase |
Three Phase |
Single Phase |
| Capacity |
1.0 KVA - 50.0 KVA |
10.0 KVA - 200.0 KVA |
1.0 KVA - 3.0 KVA |
| Input Voltage Nominal |
230 Vac |
400 Vac |
230 Vac |
| Input Voltage Range |
170 - 270 Vac |
295 - 465 Vac |
160 - 270 Vac |
| Input Frequency Range |
47 - 53 Hz |
47 - 53 Hz |
47 - 53 Hz |
| Input Power Factor |
0.95 with active filtering |
0.95 with active filtering |
> 0.95 with active filtering |
| Output Voltage Nominal |
230 Vac |
400 Vac |
230 Vac |
| Output Voltage Regulation |
± 1% |
± 1% |
± 1% |
| Output Frequency Nominal |
50 Hz |
50 Hz |
50 Hz |
| Output Frequency Range |
± 0.05% |
± 0.05% |
± 0.05% |
| Output Waveform |
Pure sinewave |
Pure sinewave |
Pure sinewave |
| THD |
< 3% (Linear) |
< 2% (Linear) |
<2% (Linear) |
| Load Power Factor |
0.8pf |
0.8pf |
0.8pf |
| Load Power Rating in KWatts |
0.8 Times KVA Rating |
0.8 Times KVA Rating |
0.8 Times KVA Rating |
| Transient Response |
± 5V / 1Cy. |
± 5V / 1Cy. |
± 5V / 1Cy. |
| Efficiency |
> 90% |
> 90% |
> 90% |
| Rectifier Charger |
CC-CV Fully automatic float cum boost charger |
CC-CV Fully automatic float cum boost charger |
CC-CV Fully automatic float cum boost charger |
| Inverter |
Adaptive sine-weighted pulse width modulated (IGBT) |
Adaptive sine-weighted pulse width modulated (IGBT) |
Adaptive sine-weighted pulse width modulated (IGBT) |
| Protections |
Under / Over Voltage, Overload / Short Ckt. |
Under / Over Voltage, Overload / Short Ckt. |
Under / Over Voltage, Overload / Short Ckt. |
| Indications |
Mains On, Inv. On, Btty. Low, Btty. On Trip |
Mains On, Inv. On, Btty. Low, Btty. On Trip |
Mains On, Inv. On, Btty. Low, Btty. On Trip |
| Metering |
Analog / Digital for Input and Output |
Analog / Digital for Input and Output |
Analog / Digital for Input and Output |
| Options |
Static bypass Software Interface |
Static bypass Software Interface |
Static bypass Software Interface |
| |
|
|
|
|